Yokogawa Pressure Transmitter Eja430e
video
Yokogawa Pressure Transmitter Eja430e

Yokogawa Pressure Transmitter Eja430e

◆Display:LCD Display
◆Fill Fluid:Silicone/Inert
◆Output: HART 4-20 mA
◆Delivery Time:2-4 weeks
◆Country Of Origin:Singapore
◆Housing Material:Aluminum/316L SST
◆Product certifications:ATEX Intrinsic Safety and Dust

Product Introduction

Products Description

 

Yokogawa pressure transmitter eja430e is a pressure transmitter, it can measure the maximum range to 16MPa, and the accuracy reaches 0.055%. It uses an intelligent microprocessor, which can exchange information with other devices through a digital communication interface. Housing is made of stainless steel, which can withstand high temperature and high pressure environments, It is designed for easy installation and maintenance, and can be set up for operation through the HART protocol. Due to its accuracy and reliability, EJA430E is widely used in industrial automation control systems.

Technical specifications

 

Measurement range

0.03 to 16 M Pa

Output signal

BRAIN, HART, 1-5 V DC

Accuracy

0.055% (standard type), 0.04% (high-precision type)

Working temperature range

-40 ° C~85 ° C

Protection level

IP67 (standard type), IP68 (explosion-proof type)

Diaphragm material

316L stainless steel (standard type), Hastelloy C-276 (corrosion-resistant type)

Power supply

10.5-42 VDC

Relevant certifications

CE, FM, CSA, ATEX, IECEx


EJA430E gauge pressure transmitter is a very important measuring instrument, it can realize the pressure measurement of liquid and gas, and transmit the measured data to the control system for analysis and processing. Due to the importance of its function, we need regular maintenance to ensure its accuracy and reliability.

Maintenance measures


  • Firstly, the EJA430E gauge pressure transmitter, like other electronic equipment, requires regular cleaning and maintenance. We can use a clean cloth or paper towel to wipe the surface, and avoid using strong acid or alkali to ensure that the surface is not damaged.

  • Secondly, the EJA430E gauge pressure transmitter should be calibrated to ensure its measurement accuracy under various conditions. Calibration should be performed using a suitable calibration device and following the manufacturer's instructions. Before calibration, it should be ensured that the transmitter and the calibration device are in the same temperature and pressure environment, otherwise the calibration results may be inaccurate.

  • In addition, if there is any failure or abnormality in the EJA430E gauge pressure transmitter, we will carry out troubleshooting and repair in time. When repairing, it is necessary to operate carefully to avoid serious damage to the equipment.

  • Finally, we should also pay attention to the working environment of yokogawa pressure transmitter eja430e. If the transmitter is exposed to humidity, dust, high or low temperatures, its performance and life may be affected. Therefore, during use, care should be taken to keep the surrounding environment clean to avoid affecting the normal operation of the equipment.

     yokogawa pressure transmitter eja430e     yokogawa pressure transmitter eja430e

For the maintenance of the EJA430E gauge pressure transmitter, we need to clean and maintain it regularly, perform calibration, repair and troubleshoot in time, and pay attention to maintaining a good working environment. Only in this way can the stability and accuracy of this key measuring instrument be ensured in the production process.

FAQ

 

1. How to install the EJA430E transmitter correctly?

(1) The transmitter should be installed upright so that gas and liquid mixtures can be excluded.

(2) The transmitter and the pipeline should be tightly connected to avoid leakage.

(3) Attention should be paid to the vibration and shock of the pipeline to ensure the stability of the transmitter.


2. How to adjust the zero point and span of EJA430E transmitter?

(1) Zero point adjustment: When the air pressure is 0, close the valve on the pipeline, and then adjust the output of the transmitter to 4mA DC.

(2) Range adjustment: After the zero point adjustment has been carried out, gradually increase the pressure and record the corresponding output current value, and then calculate according to the relevant formula to complete the range adjustment.


3. What are the common faults of the EJA430E transmitter?

Common faults of EJA430E transmitter include unstable output, zero point drift, and range drift. These faults are generally caused by loose pipelines, fluctuations in power supply voltage, or temperature changes, and need to be checked and resolved in time.


After choose yokogawa pressure transmitter ejA430e and setting parameters according to actual needs, a reliable pressure measurement system can be quickly established. Due to the use of advanced digital communication technology, this product has high data transmission accuracy, good stability, and anti-interference performance, reducing unnecessary labor and improving the accuracy and efficiency of data processing.


By using the EJA430E gauge pressure transmitter, not only has the automation control level been improved, the risk of manual intervention operations been reduced, but also the downtime and maintenance costs have been reduced, enhancing the production safety and competitiveness of the enterprise.

Hot Tags: yokogawa pressure transmitter eja430e, China yokogawa pressure transmitter eja430e manufacturers, suppliers, factory, YOKOGAWA YTA710, YOKOGAWA YTA610, Yokogawa Transmitter

You Might Also Like

(0/10)

clearall