Rosemount 8750w Flow Meter
Origin: Mexico
Manufacturer : Rosemount
Delivery Time: 6 - 8 Weeks
Product model: 8750WDMT2A2FNSA030CDEM4Q4
Product Name: Rosemount 8750W Electromagnetic Flowmeter
Product Introduction
Products Description
The working principle of rosemount 8750w flow meter is based on Faraday's law of electromagnetic induction. The measured liquid must be conductive, and the conductivity should meet the requirements of the electromagnetic flowmeter. Whether in water treatment, chemical, food and beverage or power and oil industries, it can provide accurate and stable flow measurement.
Product Features
- Comparison calibration can be performed through a standard flowmeter to ensure the accuracy of the measurement and the accuracy of the measurement results, with an accuracy of ±0.5%.
- Rosemount electromagnetic flowmeter provides a variety of lining materials (such as PTFE and Neoprene) and electrode materials (such as 316L stainless steel and Hastelloy as electrode materials), enhances signal strength and signal processing technology to adapt to different media and working environments, and can provide stable flow measurement in high noise environments.
- Supports regular calibration and calibration, which can achieve instrument verification, stability in noisy environments, and grounding and wiring fault detection to reduce measurement errors and improve the reliability and safety of equipment.
- Calibration can be verified without auxiliary equipment, thereby reducing time and cost.
- The rugged design helps reduce operating costs and the risk of unplanned downtime, reduces maintenance and replacement costs, and thus reduces overall life cycle costs.
- With an easy-to-use field operation display panel (LOI), users can perform field configuration, monitoring and diagnosis, which greatly facilitates user use.


Products Specification
|
Power supply |
90 - 250VAC @ 50/60Hz / 12 - 42VDC |
|
Transmitter coil drive current |
500mA |
|
Power consumption |
90 - 250VAC: 40VA maximum 12 - 42VDC: 15W maximum |
|
Switch-on current |
At 250VAC: Maximum 35.7A (< 5ms At 42VDC: Maximum 42A (< 5ms) |
|
Ambient temperature limits |
perating: –58 to 140 °F (–50 to 60 °C) without LOI/Display –4 to 140 °F (–20 to 60 °C) with LOI/Display |
Although the rosemount 8750w flow meter mainly measures conductive liquids, it is also possible to measure some non-conductive liquids if they contain a certain amount of impurities or can increase their conductivity through special treatment. Rosemount electromagnetic flowmeter has won wide recognition in the market with its unique advantages.
Installation and maintenance
- The flowmeter should be installed at the low point or vertical section of the pipeline, and the measuring tube must be filled with liquid to avoid bubbles affecting the measurement accuracy.
- The installation location should avoid strong vibration and magnetic field interference to ensure the stability and accuracy of the measurement.
- When installed in a full pipe, the requirement for the straight pipe section is 5D in front and 3D in the back (D is the inner diameter of the measuring pipe).
- Regularly check whether the electrodes, excitation coils and other components are connected well and whether the power supply is normal.
- Clean the electrodes regularly and replace them when necessary to prevent dirt from affecting signal acquisition. Under normal use and maintenance, their service life is usually long.
Hot Tags: rosemount 8750w flow meter, China rosemount 8750w flow meter manufacturers, suppliers, factory, Siemens Transmitter, Fisher DVC6200 Positioner, Yokogawa UT350, 1734-IB8, Honeywell STD725 Differential Pressure Transmitter, Rosemount